€645.40*
% €759.22* (14.99% saved vs. recommended price)will be ordered for you
Lead time: 7 days (according to manufacturer**),
est. total delivery time: 1-2 weeks
Product number:
1673801
EAN:
8719076022527
Manufacturer product ID:
ITR040362041
Please note that our English product descriptions are automatic translations from German. If anything is unclear, please contact us and/or double check the description by the manufacturer. Thanks for your understanding! - your Klabauter Crew
Product information "VICTRON - isolating transformer 3600 W"
· Safety and prevention of galvanic corrosion. With an isolation transformer full galvanic isolation between ship and shore power is achieved. It increases security, makes galvanic isolators unnecessary and prevents polarity problems.
· Safety is taken for granted in power grids on land. If a short circuit or a ground fault a fuse by or a ground fault circuit interrupter (GFCI) burns disconnects the circuit. The connection of the grounding line of the shore connection with the metal parts of the vessel results, as described below, to galvanic corrosion. If the ground wire is omitted and only the phase and neutral are out on board, all mentioned fuses on board are ineffective and there is no short-circuit protection more.
· Galvanic corrosion occurs when two dissimilar metals that are electrically connected to each other in a conductive liquid (an electrolyte), such as Seawater or lesser extent, fresh water are submerged.
· It is a mistake to assume that galvanic corrosion can occur only in metal and aluminum hulls. In reality, it affects all ships when metal parts such as the propeller shaft and the outer skin or metallic feedthroughs with water come into contact, and the ship is grounded via the shore connection. It may be tempting to forego be the land connection to the protective conductor: this is however extremely for the persons on board, because the guards will not appeal (see above) more dangerous.
· Soft start function and an inrush current limiter is a given at Victron isolation transformer so that problems can be avoided with high inrush currents.
· Isolation transformer 3600 W
· Input and output voltage 115/230 V *
· Frequency 50/60 Hz
· Performance 32/16 A
· Soft start yes
· Transformer type Toroidal (low noise, low weight)
· Input protection yes
· Housing material: aluminum, protection class IP21
· Weight 23 kg
· Dimensions (HxWxD): 362 x 258 x 218 mm
* Suitable for the following stress conditions: 230 V / 230 V, 115 V / 115 V, 115 V / 230 V, 230 V / 115 V
· Safety is taken for granted in power grids on land. If a short circuit or a ground fault a fuse by or a ground fault circuit interrupter (GFCI) burns disconnects the circuit. The connection of the grounding line of the shore connection with the metal parts of the vessel results, as described below, to galvanic corrosion. If the ground wire is omitted and only the phase and neutral are out on board, all mentioned fuses on board are ineffective and there is no short-circuit protection more.
· Galvanic corrosion occurs when two dissimilar metals that are electrically connected to each other in a conductive liquid (an electrolyte), such as Seawater or lesser extent, fresh water are submerged.
· It is a mistake to assume that galvanic corrosion can occur only in metal and aluminum hulls. In reality, it affects all ships when metal parts such as the propeller shaft and the outer skin or metallic feedthroughs with water come into contact, and the ship is grounded via the shore connection. It may be tempting to forego be the land connection to the protective conductor: this is however extremely for the persons on board, because the guards will not appeal (see above) more dangerous.
· Soft start function and an inrush current limiter is a given at Victron isolation transformer so that problems can be avoided with high inrush currents.
· Isolation transformer 3600 W
· Input and output voltage 115/230 V *
· Frequency 50/60 Hz
· Performance 32/16 A
· Soft start yes
· Transformer type Toroidal (low noise, low weight)
· Input protection yes
· Housing material: aluminum, protection class IP21
· Weight 23 kg
· Dimensions (HxWxD): 362 x 258 x 218 mm
* Suitable for the following stress conditions: 230 V / 230 V, 115 V / 115 V, 115 V / 230 V, 230 V / 115 V