Welcome to the international Version of KlabauterShop!
We ship worldwide directly to your boat/marina.
Send us an inquiry regarding shipping possibilities.

VICTRON - isolating transformer 7000 W

1673601
€965.90 * €1,137.00 * (15.05% Saved)

Prices incl. VAT plus shipping costs

Shipped within approx. 7 Workdays (delivery times depend on your location for international shippings)

  • 1673601
  • ITR000702001
  • 8719076022442
Safety and prevention of galvanic corrosion. With an isolation transformer full galvanic... more
Product information "VICTRON - isolating transformer 7000 W"
Safety and prevention of galvanic corrosion. With an isolation transformer full galvanic isolation between ship and shore power is achieved. It increases security, makes galvanic isolators unnecessary and prevents polarity problems.Safety is taken for granted in power grids on land. If a short circuit or a ground fault a fuse by or a ground fault circuit interrupter (GFCI) burns disconnects the circuit. The connection of the grounding line of the shore connection with the metal parts of the vessel results, as described below, to galvanic corrosion. If the ground wire is omitted and only the phase and neutral are out on board, all mentioned fuses on board are ineffective and there is no short-circuit protection more.Galvanic corrosion occurs when two dissimilar metals that are electrically connected to each other in a conductive liquid is created (an electrolyte), such as Seawater or lesser extent, fresh water are submerged.· It is a mistake to assume that galvanic corrosion can occur only in metal and aluminum hulls. In reality, it affects all ships when metal parts such as the propeller shaft and the outer skin or metallic feedthroughs with water come into contact, and the ship is grounded via the shore connection. It may be tempting to forego be the land connection to the protective conductor: this is however extremely for the persons on board, because the guards will not appeal (see above) more dangerous.· Soft start function and an inrush current limiter is a given at Victron isolation transformer so that problems can be avoided with high inrush currents.Isolating transformer 7000 WInput and output voltage 230 VFrequency 50/60 HzA power 32Soft start yesType transformer ring core (low noise, low weight)Input protection yesCasing material: aluminum, protection class IP21Weight 28 kgDimensions (HxWxD): 362 x 258 x 218 mm
[Note that this product description is an automatic translation. Please contact us if you have any questions.]

Related links to "VICTRON - isolating transformer 7000 W"
Available downloads:
Read, write and discuss reviews... more
Customer evaluation for "VICTRON - isolating transformer 7000 W"
Write an evaluation
Evaluations will be activated after verification.

The fields marked with * are required.

I have read the data protection information.

Viewed