€428.90*
% €504.56* (15% saved vs. recommended price)will be ordered for you
Lead time: 7 days (according to manufacturer**),
est. total delivery time: 1-2 weeks
Product number:
1673701
EAN:
8719076022480
Manufacturer product ID:
ITR040202041
Please note that our English product descriptions are automatic translations from German. If anything is unclear, please contact us and/or double check the description by the manufacturer. Thanks for your understanding! - your Klabauter Crew
Product information "VICTRON - isolating transformer 2000 W"
· Security and prevention of galvanic corrosion. A complete galvanic separation between the ship and the land network is achieved with a separator. It increases security, makes galvanic isolators superfluous and prevents polarity problems.
· Safety is assumed in land grid on land as a matter of course. In the event of a short circuit or an ground error, a melting fuse burns through or an residual current circuit breaker (FI control switch) separates the circuit. The connection of the land line of the land connection with the metal parts of the ship, as described below, lead to galvanic corrosion. If the earth ladder is omitted and only the phase and the zero conductor are led on board, all the fuses mentioned on board are ineffective and there is no longer any short circuit protection.
· Galvanic corrosion always arises when two different metals that are electrically conductively connected to each other are immersed in a conductive liquid (an electrolyte) such as sea water or polluted fresh water.
· A mistake can be assumed that galvanic corrosion can only occur in aluminum or steel ships. In reality, it affects all ships as soon as metal parts such as the propeller and the shaft or metal outer skin implementations come into contact with water, and the ship is grounded via the land connection. It may be tempting to do without the protective conductor in the land connection: However, this is extremely dangerous for the people on board, since the protective devices then no longer appeal (see above).
· Soft Start Function or a switch-on power limiter is a matter of course for the Victron separator that is avoided so that problems with high switch-on flows are avoided.
Separation transformer 2000 W
Input and output voltage 115/230 V *
Frequency 50/60 Hz
Performance 17/8.5 a
Soft start yes
Transformer type ring core (low noise level, low weight)
Input securing yes
Housing material: aluminum, protection class: IP21
Weight 10 kg
Dimensions (HXBXT): 375 x 214 x 110 mm
* Usable for the following tension: 230 V / 230 V, 115 V / 115 V, 115 V / 230 V, 230 V / 115 V
· Safety is assumed in land grid on land as a matter of course. In the event of a short circuit or an ground error, a melting fuse burns through or an residual current circuit breaker (FI control switch) separates the circuit. The connection of the land line of the land connection with the metal parts of the ship, as described below, lead to galvanic corrosion. If the earth ladder is omitted and only the phase and the zero conductor are led on board, all the fuses mentioned on board are ineffective and there is no longer any short circuit protection.
· Galvanic corrosion always arises when two different metals that are electrically conductively connected to each other are immersed in a conductive liquid (an electrolyte) such as sea water or polluted fresh water.
· A mistake can be assumed that galvanic corrosion can only occur in aluminum or steel ships. In reality, it affects all ships as soon as metal parts such as the propeller and the shaft or metal outer skin implementations come into contact with water, and the ship is grounded via the land connection. It may be tempting to do without the protective conductor in the land connection: However, this is extremely dangerous for the people on board, since the protective devices then no longer appeal (see above).
· Soft Start Function or a switch-on power limiter is a matter of course for the Victron separator that is avoided so that problems with high switch-on flows are avoided.
Separation transformer 2000 W
Input and output voltage 115/230 V *
Frequency 50/60 Hz
Performance 17/8.5 a
Soft start yes
Transformer type ring core (low noise level, low weight)
Input securing yes
Housing material: aluminum, protection class: IP21
Weight 10 kg
Dimensions (HXBXT): 375 x 214 x 110 mm
* Usable for the following tension: 230 V / 230 V, 115 V / 115 V, 115 V / 230 V, 230 V / 115 V